Comparison of angioplasty with infusion of tirofiban or abciximab and with implantation of sirolimus-eluting or uncoated stents for acute myocardial infarction: the MULTISTRATEGY randomized trial

JAMA. 2008 Apr 16;299(15):1788-99. doi: 10.1001/jama.299.15.joc80026. Epub 2008 Mar 30.

Abstract

Context: Abciximab infusion and uncoated-stent implantation is a complementary treatment strategy to reduce major adverse cardiac events in patients undergoing angioplasty for ST-segment elevation myocardial infarction (STEMI). It is uncertain whether there may be similar benefits in replacing abciximab with high-dose bolus tirofiban. Similarly, the use of drug-eluting stents in this patient population is currently discouraged because of conflicting results on efficacy reported in randomized trials and safety concerns reported by registries.

Objective: To evaluate the effect of high-dose bolus tirofiban and of sirolimus-eluting stents as compared with abciximab infusion and uncoated-stent implantation in patients with STEMI undergoing percutaneous coronary intervention.

Design, setting, and patients: An open-label, 2 x 2 factorial trial of 745 patients presenting with STEMI or new left bundle-branch block at 16 referral centers in Italy, Spain, and Argentina between October 2004 and April 2007.

Interventions: High-dose bolus tirofiban vs abciximab infusion and sirolimus-eluting stent vs uncoated stent implantation.

Main outcome measures: For drug comparison, at least 50% ST-segment elevation resolution at 90 minutes postintervention with a prespecified noninferiority margin of 9% difference (relative risk, 0.89); for stent comparison, the rate of major adverse cardiac events, defined as the composite of death from any cause, reinfarction, and clinically driven target-vessel revascularization within 8 months.

Results: ST-segment resolution occurred in 302 of 361 patients (83.6%) who had received abciximab infusion and 308 of 361 (85.3%) who had received tirofiban infusion (relative risk, 1.020; 97.5% confidence interval, 0.958-1.086; P < .001 for noninferiority). Ischemic and hemorrhagic outcomes were similar in the tirofiban and abciximab groups. At 8 months, major adverse cardiac events occurred in 54 patients (14.5%) with uncoated stents and 29 (7.8%) with sirolimus stents (P = .004), predominantly reflecting a reduction of revascularization rates (10.2% vs 3.2%). The incidence of stent thrombosis was similar in the 2 stent groups.

Conclusions: In patients with STEMI undergoing percutaneous coronary intervention, compared with abciximab, tirofiban therapy was associated with noninferior resolution of ST-segment elevation at 90 minutes following coronary intervention, whereas sirolimus-eluting stent implantation was associated with a significantly lower risk of major adverse cardiac events than uncoated stents within 8 months after intervention.

Trial registration: clinicaltrials.gov Identifier: NCT00229515.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Abciximab
  • Aged
  • Angioplasty, Balloon, Coronary*
  • Antibodies, Monoclonal / administration & dosage
  • Antibodies, Monoclonal / therapeutic use*
  • Drug-Eluting Stents*
  • Female
  • Humans
  • Immunoglobulin Fab Fragments / administration & dosage
  • Immunoglobulin Fab Fragments / therapeutic use*
  • Infusions, Intravenous
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Myocardial Infarction / therapy*
  • Platelet Aggregation Inhibitors / administration & dosage
  • Platelet Aggregation Inhibitors / therapeutic use*
  • Platelet Glycoprotein GPIIb-IIIa Complex / antagonists & inhibitors*
  • Stents*
  • Tirofiban
  • Tyrosine / administration & dosage
  • Tyrosine / analogs & derivatives*
  • Tyrosine / therapeutic use

Substances

  • Antibodies, Monoclonal
  • Immunoglobulin Fab Fragments
  • Platelet Aggregation Inhibitors
  • Platelet Glycoprotein GPIIb-IIIa Complex
  • Tyrosine
  • Tirofiban
  • Abciximab

Associated data

  • ClinicalTrials.gov/NCT00229515